USB-6363 not detected by NI-DAQmx on Ubuntu 22.04

Product: NI USB-6363 (multifunction DAQ)OS: Ubuntu 22.04.5 LTS, kernel 5.15.0-194-genericDriver: NI Linux Device Drivers 2026 Q3 (ni-software-2026-jammy), ni-daqmx 26.5.0.49618-0+f466, ni-daqmx-mio...

View Article


Image may be NSFW.
Clik here to view.

Part number of 68-pole connector on SCB-68A

I design a PCB as a signal conditioning unit, where the interface to DAQ system should be exactly the same connector, as mounted in the SCB-68A. I could not figure out the type and manufacturer of it....

View Article


USB-6363 AO drops to ground when USB is disconnected

I'm sure this has been asked before, but I was wondering if there was a way to change some functionality of the USB-6363. My issue is that a DC analog output (say 5 V) will drop to 0 V immediately if...

View Article

Fried the daq

Hello, Testing with my Mcc daq usb tc to read some temperatures. The thermocouple came contact into with a 120v cable and fried the daq channels. Now its giving random values but stills turns on....

View Article

NI USB-6451 OEM

With the OEM boardsNI USB-6212NI MIO USB-6423i can easy internally read back the value on AO with the task string like:Dev1/_ao0_vs_aogndwith the NI USB-6451 , i just get error -200170Physical channel...

View Article


Image may be NSFW.
Clik here to view.

RC68-68 (P/N 187252-01) – D-Type Connector Jackscrews

Can anyone please confirm whether the 68-pin D-Type (P1) connector on the RC68-68 (P/N 187252-01) is supplied with factory-installed captive jackscrews, or if it has mounting holes only?  

View Article

Accessing all 4 Analog Outputs on PCIe-6323 using a single terminal block?

Hello NI Community,I am designing a hardware setup using an NI PCIe-6323 for an auditory research experiment. My application requires 4 Analog Outputs (AO 0 through AO 3) for multi-channel acoustic...

View Article

Protecting NI-9219 DAQ from HF interference during TIG welding

Hello everyone,I am using an NI-9219 module in a cDAQ chassis to acquire temperature data from K-type thermocouples during an automated TIG welding process.The thermocouples are spot welded directly...

View Article


PE Grounding Point through cdaq 9183 Chassis

Hello,I am setting up a system based upon a NI 9183 cDAQ chassis. My aim is to build a robust system against EMC to do some analog measurements in a noisy environment.  I have connected all cable...

View Article


9216 Brief Data Dropout

During cold weather between the 30° F to 45° F range, we saw that several of our 100ohm RTDs around the site started having blips in data with a <1s persistence. All of these sensors were on 9216...

View Article

Temperature measurement with NI9237 Bridge Module

Hi, Anyone with successful experience gathering temperature data using a slot in a 9237? I have an application for full bridge measurements and would like to leverage an empty slot to capture...

View Article

6363 MHDDK Analog Read

Hi, I'm porting some QNX C++ code from a 6259 card to a 6363, using the MHDDK, and I've got digital in and out, and analog out working fine, but the analog input is proving tricky!  The code below...

View Article

PXIe-6363: Capturing digital waveform using same waveform as trigger

I want to capture a digital waveform using the PXIe-6363 internal clock at 2 Msamples/sec, triggering on a high-to-low transition of that digital waveform. I understand that the digital waveform needs...

View Article


Cannot read analog input between 0 and 0.6VDC on my USB-6008 with RSE mode

I'm trying to read analogue input via RSE connections with floating signal sources (battery device). And the input signal meets all of the following conditions:The input signal can share a common...

View Article

Differences between 64xx and 63xx multifunction hardware

I have a project that has been using a USB-6341 successfully for a several years. It does some straightforward hardware timed DO, bit-banging a protocol at ~1 MBit data rates for some really low-level...

View Article


Convert the analog signal output of the PCIe-6733 board to an SMA connector.

Hello. I am building an analog signal output system for ultracold atom experiments. I plan to use a PCIe-6738 to generate signals, and use an SHC68-68-A2 cable to connect the signals to an SCB-68A...

View Article

PCI‑6562, two independent tasks with external trigger

Hello,I have been working with the NI PCI‑6562 card in LabVIEW for quite a long time. I would like to use the card to synchronously generate two independent tasks on the same DIO lines. The trigger for...

View Article


Using a PT100 RTD with LabJACK U6 Pro

Hi,  Can I read the temperature off a PT-100 RTD connected to a LabJACK U6 Pro?  I can easily do it with a type K thermocouple using the OpenLJ VI, but I want to do it with a Resistance Temperature...

View Article

Is NI DAQ 6211 supported by DAQmx 2026Q2 on Linux?

I've installed the DAQmx drivers and hardware configuration utility (2026Q2) on a Ubuntu 24.04 new installation. The installation seemed to work fine. However, when I tried to attach my NI USB 6211 DAQ...

View Article

Trying to replace a PCI-6220 with a USB DAQ device for triggered analog...

Hello, I'm trying to find a suitable DAQ device to relace a PCI-6220 for an analog voltage application. The present application is a classroom experiment to measure the lifetime of cosmic ray muons. We...