nilsdev finds nothing, error -52026

Hi all, Under Scientific Linux 6, x86_64, nlsdev reports no devices.$ nilsdev -v-52026Error code could not be found. Reinstalling the driver might fix the issue. Otherwise, contact National Instruments...

View Article


NI PCIe 6321

Hi im planning to buy a NI DAQ PCIe 6321 , i'm want also to buy accessories like bnc terminal and shielded cable .would this combinaison work properly . NI PCIe-6321...

View Article


Input range for a PXI-6071e in DAQmx

HiI’m not sure if this is the right group to be posting to, so my apologies if I’ve got this wrong. I’m in the process of converting routines written in Labview 7.1 to 2014, which has also meant...

View Article

Control analog output of a voltmeter using NI-6211

Hi I am trying to control the output on a voltmeter using NI-6211. I have tried with the DAQ assistant in a while loop wired to a control, and also tried to simulate a signal, but I could not see any...

View Article

PXIe-6363 Analog Output with galvanic separation possible?

Hello, my question is about the PXIe-6363 which is used in a PXIe-Chassis. We have to control an amplifier with a analog output of the PXIe-6363. The input of the amplifier is high ohmic but connected...

View Article


SCB-68 Shielded Desktop Connector Block Issue

I have an adapter question regarding the NI SCB-68 Connector Block.  These connect to older PC's via 68-pin I/O connector.  Is there a way to convert these old models to USB via some kind of 68-pin...

View Article

DAQ Analog output not returning to 0

I have a USB 6343 and I am using the analog output to continuously put out a waveform that includes some pulses and then a return to 0.0V baseline at the end of the cycle.  I use Task.Stop() to stop...

View Article

How to find "Base Address" in DAQmx property nodes

I am trying to convert old code that uses T-DAQ to DAQmx, and I'm running into a problem with "Get DAQ Device Information.vi".  The code outputs the "Base Address" using this VI, but I can't seem to...

View Article


Image may be NSFW.
Clik here to view.

lv2016, sampleclk of DAQ not initializing anymore

Hi all,I am a beginner in labview. I am using a cDAQ-9188 and since I transfered a VI from lv2014 to lv2016 which initialize the DAQ, the sample clock is not initialized anymore.Is this a known bug?...

View Article


NI 9205 card is not recognized by MAX/ "Error 201003 occured at DAQmx"

Hello  I am using MAX version 15 for labview 2015. The program is used for controlling fans, spark ignition and reading temperature and pressure. 5 NI cards such as NI 9205 are used in the DAQ system....

View Article

Regarding persistance of output signals, are updates necessary?

When a task generates an output signal on a channel, does it stay there indefinitely? Suppose I destroy the task and create a new task to output a signal on another channel, is the first signal...

View Article

Error -200279 Analog Input, DAQmx API

I'm writing a plain C application using the DAQmx API. I've modified the sample TDMS-ContAcq-IntClk Example program to give me multiple channels (4 channels in this case). It keeps giving me buffer...

View Article

MII DataLab IO - Cheap alternative to NI cDAQ hardware?

Hello,I would like to ask if anyone have experience to use hardware from Moravian Instruments (MII) with LabVIEW (instead of MII's software Control Web 7). Hardware is not so fast but includes a lot of...

View Article


MII DataLab IO - Cheap alternative to NI cDAQ hardware?

Moved to another board

View Article

How to disconnect A PFI line from counter output

I am using a USB-6363 programmed with Labview. I have a setup that requires me to output a pulse generated from ctr2 on one of four different PFI lines (PFI1, 2, 3, or 4).  In the task setup, I wire...

View Article


Multi Channel AI and AO Issue

Unfortunately it appears I have fallen into the trap of forgetting that more than one DAQmx task can't be started on the same device.  I have a situation that I need to be able to read and write...

View Article

Data acquisition

Hi there,Im using NI USB6008 for data acquisition from 6 devices sampled at 1000Hz. Every time I started the process, after like 20 - 30 seconds, this error message will  pop out 'No transfer in...

View Article


Generating a Digital pulse train for triggering camera and syncing analog I/O

Hi,  I have the following components: 1. NI PCI-6713 connected to a BNC-2110 2. cDAQ 9174 + NI 9205 + NI 9264. I want to generate a digital pulse train at a 30 Hz. and feed that signal as a trigger...

View Article

NI 9205 DAQ with incremental Encoder

Hi everybody, I am pretty new to DAQ and a little stuck at the Moment. Maybe somebody can point me in the right direction.What I basically want to do is to run an asynchronous measurement of a...

View Article

Data acquisition stops during single pulse output (long pulse = 10 hours) [NI...

Hello, guys. I am facing some problems when trying to create a VI for data acquisition and controlling a relay.I want to measure the voltage of a battery during charge and discharge. During the...