NI-6733 Higher analog output rate for a given time
Hello, I am using the NI-6733 card for analog output and i am currently trying to figure if it's possible to go to a higher output rate that the one specified (Max update rate is 1MS/s) for a short...
View ArticleLabview multiple channel measurement malfunction: NI USB-6259
Hi there, I am currently working on a project which requires measuring analog inputs off of 29 different channels in LabView on an NI USB-6259 DAQ. In my LabView code, I am using the DAQmx read...
View Articlehow to set the scale of NI 9025 by CRIO 9035
now,i have a project with NI production,i need sample data form NI 9025 by CRIO 9035,i know NI 9025 have some different scales,but i don't know how to set special scale by CRIO 9035.
View ArticleData Acquisition and Plotting using USB-6000 and Qt 5
Hi,This is my first question so please bear with me.I wanted to know if anyone tried to plot the data(analog voltage In) continuously acquired from the USB-6XXX on the QwtPlot?If yes what steps should...
View ArticleProblem with the measurement & autamation explorer
Dear Community,We are dealing with gravimeters, devices that measure absolute value of gravitation. After the last “upgrade” of the manufacturer they changed the internal barometer and the temperature...
View ArticleDAQmx Timing VI
Using NI 9263 board. The previous programmer has wired 2000 to the samples per channel and 100 to rate.The VI is being used to generate a waveform. Would someone explain to me why both values are being...
View ArticleUsing Continuous Sampling in NI DAQmx, using Python, with NI USB-6251 DAQ board
Hey everyone, I am trying to set up a Read function on an Analog Input pin, in a loop, with the goal of being able to collect and handle pseudo-continuous data for an 8-hour period (overnight). To do...
View ArticleSCB-68 is capable to apply my recorded signal to the real world again?
Hello. I have SCB-68E series DAQ and 6221 board. I use my daq with Labview 2013. I recorded a signal with my daq as text file. And now i want to use this signal. So i need the use this signal as output...
View ArticlecDAQ 9185 and NI9205/9476 module
Hi Everybody, I am running into some problems with the cDAQ 9185 when using it with labview 2015. When using the DAQ assistant and configuring the cDAQ for voltage input, I get the message error code...
View ArticleBALLARD MIL-STD-1553 PCI LABVIEW FILES SUPPORT
HI, I i have inserted MIL-STD-1553 PCI card in slot and installed drivers for LX1553-5 .BTIdriver librarys given with installation drivers are labview 8.6 and labview 2010.But labview version in my pc...
View ArticleVoltage measurement (AC) using cDAQ-9172 with NI 9221 (+- 60 V)
Hi,I must read a voltage signal (0-16 V AC across the terminals), and I have the NI-9221 at hand (datasheet: http://www.ni.com/pdf/manuals/375905a_02.pdf). However, this can only read single-ended...
View ArticleError code 100 - erroneous data when use the "read from measurament file"!
Hello. I record an data from my EMG amplifier with daq scb-68. When recording i used "write to measurement file" tool and i record my data as "test_1.lvm". Then i wanted to see my data on real...
View ArticleUSB-6001 Circuit Diagram
Hey guys, I recently recommended a USB-6001 to a client for a piece of software I wrote for him in LabWindows, however he would like a complete circuit diagram of the device before he purchases it....
View ArticleNI DAQ fails to recognise USB-6002 hardware
Anyone seen anything like this before?Transferring a very simple measurement application onto the target PC. Installed NIDAQ1711f0 which then made multiple duplicate copies of the hardware, each copy...
View ArticleESD affecting DAQ USB 6002
Hi, I am using the USB-6002 DAQ in a system. My system connects to some of the analog and digital pins and then the DAQ is connected to the Tablet via a USB cable.All this is fully enclosed in an ABS...
View ArticleSystem error 50502 using PXIe 6368 Cards with PXIe 8880 controller
Hi allI am using 07 PXIe-6368 DAQ Cards with PXIe 8880 Conroller (8 GB RAM) installed in PXIe-1078 chassis for simultaneously acquiring 100 channels data in finite mode (with Trigger mode Enable )...
View ArticlePCI-6115 with option code -52
I have a PCI-6115 card with part number 184529J-52. What does the option code -52 represent? It does not seem to be a memory upgrade, because the card returns the same input buffer size as my -01 card...
View ArticlePCI-6289 Troubleshooting
Hello, I have inherited a PCI-6289 in my lab group to run a NI Breakout Box for the purposes of collecting photodetector and trigger data. To do this I have been using a Python script that has worked...
View ArticleNI 9214 as stand alone?
Hello everybody,my name is Michael, I'm a student with little to no experience with data aquisition who has been given the task to figure out, which type of connector/adapter is required to directly...
View ArticleIs there a 64-bit DAQmxSetReadOffset()?
Seven years ago I suggested that the DAQmxSetReadOffset() function be upgraded from a 32-bit to a 64-bit integer....
View Article