DAQ card with independent voltage range settings for each input channel
Hello!Can anyone recommend an atleast 12bit 4channel DAQ card that has independent control over the voltage range settings for each input channel? regards, Alex
View ArticleCan I program a DAQmx sample rate on the fly while the card is acquiring
I have a USB 6003 DAQ produc tthat i am programming wiht DAQmx. Is there a way to start an acquisition with a TDMS log and the change the sample rate of the device wihtout stoppping the acquisition or...
View ArticleWhat is the best way to Sync Digital Output(TTL) with Analog Output?
I am trying to generate Analog waveform that synchronize the rising edge of a digital signal(TTL). The ttl will be used as trigger for camera. The board I have is USB-6343X. In my draft, I used a...
View ArticleHow to generate an externally triggered analog output pulse with an amplitude...
Goal I have an external trigger signal for an M-series PXI-6289 module and I would like to generate an analog output pulse each trigger. The amplitude of this pulse should be the cumulative sum of an...
View Articleupgrade 6036e
is there an upgrade procedure for 6036e ?We must replace a PCI 6036e daq card in an old labVIEW 8.6 system
View ArticleWriteDigChan-ExtClk
Hello, I ran the sample programC:\Users\Public\Documents\National Instruments\NI-DAQ\Examples\DAQmx ANSI C\Digital\Generate Values\Write Dig Chan-Ext Clk, but got a message as below: DAQmx Error:...
View ArticleControlling Servo Hydraulic Motor by NI 9263
Hello everyone, I have a 5-Axis simulator, uses five "Global Servo Hydraulic 550" motor, and I want to control them with two NI 9263. I have cables with one end of MS3106F14S-2S and one end of...
View ArticleLabview NI-Daqmx can't locate my Daq board
Im using a MicroDaq USB 1208LS, and am attemtping to monitor a pressure sensitive resistor using the "continuous measurement and logging" premade .Vi in labview. However the program doesn't recognize /...
View ArticleNI-DAQmx installation fail: NIMDFBINDIR is undefined
My installation o f NI-DAQmx fails with the following message Fatal Error!! Required NIPathsDir property NIMDFBINDIR is undefined. I have tried 9.8.0 and 14.5, both have the same issue. Running 32 bit...
View Articleni 6229 bnc analog input
Hi all,I have a pressure sensor with 2 cable.One is for power supply other is for signal.I have connected the + side of sensor to power supply +. And signal cable to ai0.I have to connect power supply...
View Articlehow do i wire a sensor to my daq having pulse output
Hi allI am using NI 6229 BNC DAQ and i have a flowmeter which is giving me pulse as output.In attachment i am sending the datasheet of sensor. How can i wire it to my daq Regards,Seyfi
View Articlecounter task for pulse output
Hi all,I have a sensor giving me pulse as output so i need counter task.I am new in labview and can you give me some examples and explain me spesifications of counter task?What are the things that need...
View ArticleNI USB-X 6353 AO 0 generates signal unintentionally
Yesterday, while I was working with NI USB-X 6353, I realized that the analog output channel 0 generates voltage reluctantly. When I reseted the device, it started generating signal immediately again,...
View ArticleHysteresis measurement with metal plate
Hi, all. I have task to figure out. I want to measure Hysteresis of elastic coupling. For measure torque I have two strain gages on 90 degrees (NI 9237 Half Bridge II). After little calculation I now...
View Articleerror 50103 on USB 6251
When I added the bottom most program, I began getting this error. What do I need to do to make this program work? Any help would be greatly appreciated.Thank you!
View ArticleUSB-6501 not seen by MAX
Hello all! I have a PC running XP 2002 (SP3) with two USB-6501 DAQs connected to it. I can see both devices in the DEVICE MANAGER under the heading "Data Acquisition Device" and both appear to have...
View ArticleHow can I set iex source and value? And what is this shift means?
We use accelerometer (PCB 352C34) with NI9234. But we don't know about iex setting. Also meaured data is shifted like screenshot. How can we remove this shift? I'm sorry for my terrible english
View ArticleParallel thermocouples connected in NI 9213
Good morning,How to connect to one of the channels, in module Ni 9213, five thermocouples connected in parallel to mesure the average temperatura of room? The others channls is occupied for other...
View ArticleChannels got influenced by each other
Hi guys, I'm quite new to LabVIEW, recently i'm setting up a small system to measure the pressure and temperature simultaneously. A PCI-6071E card is used, AI0 and AI1 are connected to pressure...
View ArticleConfigure Quadrature encoder X4 of PCI 6259 in Xenomai
I'm currently working on a project where I must set up PCI 6259 in real-time Linux Xenomai, probably with analogy library. The development environment is C++ in QT. I manage to implement analog output...
View Article