Hi, I have four (4) NI PCI-6110 cards in a 32-bit PCI expansion chassis which is connected to my PC (Win7).
When I open the NI MAX software, the cards are all visible, and are located in slots 2, 3, 4, and 5.
When I use the test panel for cards in slots 2 and 3, I have no problems, all AI on both cards function normally.
When I try to use the test panel for cards in slots 4, and 5, the test panel freezes when I press "start" for a few moments, then gives me a timeout error 200474 at test panel.
However, once I clear the error and press "start" again, the cards seem to function normally, I can apply a signal and see the waveform appear in the test panel for all AI.
This is a problem when I go to use our in-house data acquistion software, and try to address one of the channels of one of the cards in slots 4 or 5, the software crashes.
Our in-house software has no problem acquiring data from the cards in slots 2 and 3 however.
We have multiple system with the exact same setup and do not have this issue.
It seems like something is always trying to use a resource on the cards in slots 4 and 5, but I'm not sure.
I tried updating to DAQmx 15.1, and uninstalling and reinstalling the cards. I also tried swapping the cards around to different slots and removing cards. I also tried different RTSI cables, but no luck.
Can someone help me out? Thanks.
Evan
Instrumentation Engineer