Unable to apply publish properties for item "nationalinstruments.common.native".
Hello Everybody Please Read The Subject, I got is Warning from by VS2010 Express (VB.net). It seems like, the program runs and the USB-DAQ send data to my application.But why I got the warning I try...
View ArticleProblem in output more then 16 waveforms
Hello, i made a program to output 30 waveforms, but when i try to output more then 16 signals, the program show the error Internal Software Error occurred in MIO software. Please contact National...
View ArticleDAQ assistant missing even after installing DAQmx 14.0 f1
Hi, I am currently using NI LabVIEW 2015 Student Edition. I have a NI USB-6009 DAQ card and it came with an installation CD labelled NI-DAQmx 14.0 f1. So after installing the software from the CD, I...
View ArticleNI 9191 and 9215 Ad Hoc Setup Problems
We are trying to setup a NI 9191 with the 9215 module over an ad hoc network to run it on the iPad app. When we setup the hardware and have it all connected, MAX shows that the 9191 is broadcasting the...
View ArticleNI PXIe-6341 Floating Increasing/Decreasing Voltage Reading
Hi, I am having difficulty getting a proper voltage reading on my 6341 Analog inputs. The inputs seem to show values that don't correspond with that I expect, and the DAQ also seems to force the...
View ArticleProblem in output more then 16 waveforms
Hi, i made a program to output 30 waveforms, i`m using two NI 9264 but when a i try to output more than 16 signals the program show the error Internal Software Error occurred in MIO software. Please...
View ArticleNeed example source for SPI design with NiDAQ
Hi,I'm trying to use the PXIe-6363 as a SPI master. My Python software framework does not allow for a bit-banging approach. I need to output the waveforms for the CLK, MOSI, and SS lines while...
View ArticleUSB 6210 reading impossible values or flatlining at -10V with RSE
I am using an NI USB-6210 with Matlab. I have configured the analog inputs to be RSE and I have two inputs on ai0 and ai15. Ai15 is plugged directly into the board ground and I am touching the +...
View ArticleCorrectly Setting the 'Rate' Parameter of " DAQmxCfgSampClkTiming' for Signal...
Hi, I am in the process of rewriting some legacy NI-DAQ code to work in NI-DAQmx in VB6 (using NI USB-6212). Basically, I want to acquire a square waveform (2kHz, 50% duty cycle, 11 volts...
View ArticleDeploying Both NI-DAQ and DAQmx Drivers/Software to Target XP machines
Hi, I have a data acquisition VB6 program, written for the NI-6062E, that's presently being deployed to XP machines. I am in the process of rewriting the code (still in VB6) so it works with a...
View ArticleDiffenernce / choice between using a Shielded connector block (BNC 2120) or...
Hi, we are building a new laboratory setup which will require Hardware in the Loop data sensing by the sensors , and formatting/ analysis using programs and possibly sending data back to hardware for...
View ArticleUSB protocol of the USB-6001
Hi, I've got a USB-6001, and would like to use it under Linux, preferably with the comedi library. Apparently for now neither the NI DAQmx (base) driver nor comedi support this device. All I could find...
View ArticleNI 9485 Circuit Issue
I have an issue with an NI-9485. I am trying to us it to turn on a High Voltage AC relay. I have the +24V need to run the HV relay to CH0a. CH0b is connected to the positive of the HV relay's coil....
View Articleinternal memory manager error
Fatal error: NI-Memory Manager Forced Fatal Error:Internal memory manager error. .\source\nimm\tNIHeapPageManager.h:84 I received the following error when I tried to run Waveform & Data Logging...
View ArticleDAQ interface for -40C to +70C
Hi, I am seting up a life test in an environmental chamber; the temperature range will be be -40C to +70C. The UUTs are pressure transducers so accuracy of the measurements is crucial. I will be...
View ArticleNI MAX experienced an internal error and cannot load the page.
Hi, When I click on either PCIe-6321 devices in MAX I get the following screen. I found this issue http://digital.ni.com/public.nsf/allkb/5714DAA369C56A5286257E6F0078E3FA. It does not apply because I...
View ArticleNI 9219 reads maximum in current mode
Hi, we are using a NI 9219 module for current measurements. We have 2 position sensors and 2 flow meters connected to one module. We have 3 systems containing 3 modules. Normally everything works...
View ArticleNo data acquired from a single-ended sensor
Now I have trouble with connecting a HIH-4000 relative humidity sensor to my NI DAQ equipment (PXIe-6341 hooked up with a SCB-68A).Manual of HIH-4000 can be found here...
View Articleremote programming
Hi, Now I have a customer who needs so called "remote programming" and I need your help to know if LabVIEW can do it. Customer is in a group working to develop some program for workers in the...
View ArticleSCXI-1104C
Hi, Got a running system with an SCXI-1104C module. I now have some measurement errors I never had before. As a spare unit I have a SCXI-1104 (no "C")... Is it direct compatible with the system ? Can...
View Article